FGCEVDP6MMRM/00I -UPS EVO DSP PLUS RACK MOUNT 6.0 – PF 0.9 – MADE IN ITALY
- Complete protection from blackout, voltage fluctuations (overvoltages and undervoltages), lightning (with upstream arrester), frequency variations, surge, harmonics, voltage distortions
- Recommended for Local Area Networks (LAN), Data Centers, Industry, Electromedical Equipments
- Intelligent slot for SNMP, Dry Contact or MODBUS card
- On-Line Double Conversion technology transformerless (VFI-SS-111)
- Active PFC circuit (0.99)
- Compatibility with generator
- Static bypass
- Formaro Rack 19 “
UPS EVO DSP PLUS RACK MOUNT 6.0 – Power 6 KVA PF 0.9. On Line Technology (VFI) DSP, 94% Efficiency, Input / output 230 / 230Vac 50 / 60Hz, dimensions 43.8×8.8×50 cm (2 Rack units), weight 15 Kg, does not include batteries, for bacup time add external battery boxes. Multifunction graphic LCD display, static bypass, EPO contact for emergency shutdown, USB and RS232 communication ports for UPS control and on / off programming via the free TecnoManager software. SNMP, Dry Contact or MODBUS card (optional).
Technical specifications
Code / Part Numbe |
FGCEVDP6MMRM/00I |
| Nominal power | 6 KVA |
| Active power | 5,4 KW |
| Power factor | 0,9 |
| Technology | On-Line Double Conversion transformerless (VFI-SS-111) |
| Cooling | Fan cooling |
| Audible noise | 48 dBA to 1 m |
| Dimension (UPS) WxHxD | 43,8×8,8×50 cm (2U) |
| Dimension (with packing) WxHxD | 59x22x71 cm |
| Weight | 15 Kg |
| Equipped with | 1 serial cable, Tecnomanager software and 2 metal handle for 19’’ Rack cabinet mounting |
Input FGCEVDP6MMRM/00I |
|
| Number of phases | 1Ph+N |
| Nominal voltage | 208Vac/220Vac/230Vac/240Vac |
| Input voltage range | 176Vac-300Vac from 50% to 100% load, 110Vac-300Vac from to 50% load |
| Nominal frequency | 50/60 Hz (selectable) |
| Input frequency range On-Line mode | ±7% |
| Input power factor | 0,99 |
Output FGCEVDP6MMRM/00I |
|
| Number of phases | 1Ph+N |
| Nominal voltage | 208Vac/220Vac/230Vac/240Vac |
| Voltage Regulation at 0 linear load (On-Line and Battery mode) | ±1% |
| Voltage THD | 3% (linear load), 6% (non-linear load) |
| Crest factor | 3:1 |
| Frequency | 50/60 Hz (selectable) |
| Frequency stability | ±0,1 Hz |
| Inverter waveform | Sinewave |
| Overload capability (Line mode) | 110% for 10 minutes, 130% for 1 minute, >130% for 1 second |
| Overload capability (Battery mode) | 110% for 30 seconds, 130% for 10 seconds, >130% for 1 second |
| Efficiency | 94%, calculated in double conversion mode at 100% load to 100% load according to standard 62040-3 |
| Transfer time | 0 ms (On-Line) |
| Output connections | Terminal block |
Battery (fitted inside the external Battery Box) |
|
| Batteries number | 16 (inside the external Battery Box, for UPS operation) |
| Battery charge time (typical) | 6-8 hours |
| Extended autonomy | External Battery Box (optional) |
Environmental specification FGCEVDP6MMRM/00I |
|
| Working temperature | Da 0 a 55 °C (recommended from 20 to 25 °C) |
| Humidity | 95% without condensation |
| Maximum altitude | 3000 m |
| IP protection | IP20 |
| Certifications | CE (standards: Low Voltage Directive IEC EN 62040-1; EMC Directive IEC EN 62040-2; classification IEC EN 62040-3) |
Why we use Tecnoware FGCEVDP6MMRM/00I 6KVA ups ?
A 6KVA (6 kilo-volt-ampere) Uninterruptible Power Supply (UPS) is used for various reasons and applications where a reliable power source and backup are essential. Here are some common scenarios where a 6KVA UPS might be used:
- Small to Medium-Sized Offices: A 6KVA UPS can provide backup power to essential office equipment such as computers, servers, networking devices, and communication systems. It ensures that these devices remain operational during power outages, preventing data loss and maintaining productivity.
- Home Offices: If you have a home office with multiple computers, printers, and other electronics, a 6KVA UPS can offer protection against power fluctuations and outages, allowing you to continue working without interruptions.
- Retail Environments: Retail stores often use UPS systems to ensure that point-of-sale (POS) systems, cash registers, and electronic payment terminals continue to function even during power disruptions.
- Medical Facilities: Certain medical equipment, such as diagnostic devices, patient monitoring systems, and critical life-support equipment, require uninterrupted power to ensure patient safety and well-being.
- Server Rooms: In small server rooms or data centers, a 6KVA UPS can provide temporary power during brief outages, allowing administrators to safely shut down servers or switch to backup systems.
- Remote Locations: If you operate in a location with unreliable power infrastructure, a 6KVA UPS can serve as a buffer against power fluctuations and outages, helping to maintain stable operations.
- Telecommunication Infrastructure: UPS systems are crucial in telecommunications to maintain network connectivity and prevent service disruptions.
- Industrial Equipment: Some industrial equipment, such as automated machines, manufacturing processes, and control systems, require continuous power to prevent damage and ensure smooth operations.
- Security Systems: Security cameras, access control systems, and alarms often rely on uninterrupted power to ensure continuous monitoring and protection.
- Laboratories: Research and testing laboratories may use UPS systems to safeguard sensitive equipment and experiments from power interruptions.
- Audio-Visual Systems: In settings like conference rooms, auditoriums, or entertainment venues, a 6KVA UPS can provide power to audio-visual equipment, preventing interruptions during presentations or events.
- Remote Monitoring Stations: UPS systems are used in remote monitoring stations for various purposes, such as environmental monitoring, weather stations, and remote sensing equipment.
Additional information
| Ups Capacity |
6 KVA |
|---|


Reviews
Clear filtersThere are no reviews yet.