Best price Eaton 9390 UPS (uninterruptible power system) 40 – 160 kVA

BrandEaton
18 People watching this product now!
Category:
Description

Eaton 9390 UPS Formerly Powerware 9390 UPS

The 9390 IT offers data centers and facilities greater flexibility and simplicity than ever before. Not available on competitive UPSs in this class, the 9390IT delivers simple plug-and-play power connections and expansion. Now data centers and facilities no longer need to hire expensive electricians when adding equipment racks or changing floor layouts. By simply plugging in a compatible extension cable and/or ePDU, new racks can be powered in a matter of minutes. The 9390IT provides superior protection and efficiency through transformerless design and sophisticated sensing and control circuitry. The 9390IT delivers 99 percent efficiency, compared to 92 percent for the same-sized competitive UPS. The 9390IT also provides optimal efficiency across the UPS load range, meaning it maintains high efficiency down to the 20 percent load level. The 9390IT enables you to yield significant savings on day one, and not after years of expansion to full capacity.

Eaton 9390 UPS – Features

Delivers 99% efficiency without sacrificing reliability using Energy Saver System

  • Provides stronger power performance with optimum generator sizing, PFC power supply compatibility, and via lowest THD that enhances compatibility with upstream power systems
  • Offers the highest reliability and availability with Powerware Hot Sync paralleling, superior battery management, inherent redundancy and a scalable architecture that adapts to increasing power requirements
  • Delivers robust manageability with superior control and connectivity and with a superior service offering
  • Works with the Intelligent Power Software Suite, which offers free monitoring, management and shutdown software ideal for protecting physical and virtual machines

Full tech specs

UPS RATING (0.9 POWER FACTOR)

KVA

20/40/80/120/160

KW

18/36/72/108/144

GENERAL CHARACTERISTICS

EFFICIENCY

99% with Energy Saver Mode

Click here for efficiency chart

PARALLEL CAPABILITY

Four modules with tie cabinet

AUDIBLE NOISE

65 dBA @ 1 meter

ALTITUDE (MAX)

2000m at 104?øF (40?øC)

INPUT CHARACTERISTICS

VOLTAGE

208, 380, 400, 415, 480, 6001

VOLTAGE RANGE

+10% / -15%2

FREQUENCY RANGE

55-65 Hz

POWER FACTOR

0.99 (min)

INPUT CURRENT DISTORTION

SOFT START CAPABILITY

Yes

INTERNAL BACKFEED PROTECTION

Yes

BROADCAST GLOBAL SUPPORT

Yes

OUTPUT CHARACTERISTICS

VOLTAGE

2083, 3803, 4003, 4153, 4803, 6004

REGULATION

?ñ1%

INVERTER

PWM with IGBT Switching

VOLTAGE THD

2% (100% linear load); 5% (non-linear load)

LOAD POWER FACTOR RANGE

Down to 0.9pf leading without de-rating

HEAT DISSIPATION (BTU/HR X 1000/HR)

80 kVA, 208V: 23.6
160 kVA, 208V: 47.3
80 kVA, 380-480V: 21.9
160 kVA, 380-480V: 43.8

BATTERY

BATTERY TYPES

VRLA, AGM, Gel, Wet, Eaton batteries also available

BATTERY VOLTAGE

384-480V

TEMPERATURE COMPENSATION

Optional

CHARGING METHOD

ABM Technology

DIMENSIONS AND WEIGHTS

40-80 KVA MODULES

HxWxD: 73.7 x 18.9 x 31.6 in./1872 x 480 x 803 mm

40-80 KVA MODULES

640 lb./290 kg (208V); 568 lb./258 kg (480V)

120-160 KVA MODULES

HxWxD: 73.7 x 35.6 x 31.6 in./1872 x 904 x 803 mm

120-160 KVA MODULES

1,060 lb./481 kg (208V, 480V)

SERVICEABILITY

BACK/SIDE AGAINST WALL INSTALLATION

Standard

CERTIFICATION

SAFETY

UL1778, cUL

EMC

IEC62040-2 EN50091 Class A (restricted access)

SURGE

ANSI C62, 41 Cat. A&B

OPTIONAL ACCESSORIES

Module tie cabinet, external maintenance bypass, integrated distribution cabinet, isolation transformer

PREDICTPULSE REMOTE MONITORING SERVICE

24×7 remote monitoring of UPS and battery alarms, online dashboard for real-time updates, mobile app for alarms and monthly report.

COMMUNICATION OPTIONS

SOFTWARE COMPATIBILITY

Intelligent Power Manager, FORESEER, Power Xpert

COMMUNICATION CARDS

Standard system includes one ConnectUPS Web/ SNMP/-X Card with an Environment Monitoring Probe. Two communications bays standard. Four communication bays included. The following connectivity card options can be installed at any time: Modbus Card

  • Relay Interface Card (Use for AS400’s)
  • Industrial Relay Card (5A@120V)
  • Hot Sync CAN Bridge Card (provides CAN communications, isolated RS-485 port)
  • Environmental Monitoring Probe (EMP)

REMOTE INPUTS/OUTPUTS

Two building alarms inputs and one summary alarm contact (5A@120V) standard; Four more building alarm inputs available with the Communications Expansion

OPTION REMOTE PANEL

Eight backlit status indicator lamps plus an audible horn