Eaton 9155 UPS Backup Power System
The Eaton 9155 UPS provides premium online backup power and scalable battery runtimes for IT and electrical engineering infrastructure in corporate, healthcare, banking and industrial applications. Packing maximum battery runtime into a very small footprint, the 9155 UPS is a complete power protection solution. The 9155 can be equipped with an integrated, customizable power distribution module that includes a maintenance bypass switch.
Eaton 9155 – Features
- Delivers a complete solution in a sleek tower design that includes internal batteries and an integrated power distribution module
- Offers industry-leading power density with small footprint and more power capacity than comparable UPSs
- Provides more real power in less space with high 0.9 output power factor
- Extends battery service life with ABM technology that uses an innovative three-stage battery charging system
- Enables paralleling of up to four 9155 UPSs for additional capacity and redundancy
- Offers scalability with 8 to 10 kVA and 12 to 15 kVA capacity upgrades
Full Technical Specifications Eaton 9155
GENERAL |
|
| TOPOLOGY | Double-conversion Brand Eaton |
| COLOR | Black |
| RATING (VA/WATTS) | Up to 15000/13500 |
| DIAGNOSTICS | Full system self-test at startup |
| UPS BYPASS | Automatic on overload or UPS failure |
| WARRANTY | Two-year factory warranty |
| CONTENTS (SHIPS WITH THE FOLLOWING ITEMS) | 1 ready-to-go UPS, software suite CD, user guide |
| EFFICIENCY | Up to 91% |
ELECTRICAL INPUT |
|
| CONNECTION | Hardwired – see manual for terminal block layout |
| FREQUENCY | 50/60 Hz (45 to 65 Hz) |
| FREQUENCY RANGE | 45 to 65 Hz |
| INPUT POWER FACTOR | P.F >0.99 typical, >0.96 frequency converter |
| GENERATOR COMPATABILITY | Yes |
ELECTRICAL OUTPUT |
|
| OUTPUT VOLTAGE | 100/200, 110/220, 120/240 Vac 180° phase displacement; 120/208, 127/220 Vac 120° phase displacement |
| OUTPUT RECEPTACLES | (1) PDM |
| ON UTILITY VOLTAGE REGULATION | Output voltage regulation ±1% Static; ±5% dynamic at 100% resistive load change |
| ON BATTERY VOLTAGE REGULATION | Output voltage regulation ±1% Static; ±5% dynamic at 100% resistive load change |
| OVERLOAD CAPACITY | 150% for 5 sec / 125% for 1 min (online), 110% for 10 min |
| VOLTAGE WAVE SHAPE (ON BATTERY) | Sine Wave |
| TRANSFER TIME | 0 ms |
BATTERY |
|
| BATTERY MANAGEMENT | ABM technology |
| BATTERY TYPE | 9Ah, sealed, lead-acid, maintenance-free |
| BATTERY REPLACEMENT | Field-replaceable |
| START ON BATTERY | Allows start of UPS without utility input |
| RECHARGE TIME | Internal battery: approximately 3 hours to 80% usable capacity at nominal line voltage after full load discharge External battery: no more than 10x discharge time to 90% usable capacity at nominal line voltage after full load discharge |
COMMUNICATIONS |
|
| USER INTERFACE | LCD Display with blue backlight |
| LEDS | (4) LEDs for notice and alarm |
| AUDIBLE ALARMS | Yes |
| COMMUNICATION PORTS | (1) RS-232, (1) relay contact, (1) REPO, (2) environmental input |
| COMMUNICATION SLOT | (2) X-Slot communication bays |
| POWER MANAGEMENT SOFTWARE | Bundled Software Suite CD |
ENVIRONMENTAL & STANDARDS |
|
| AUDIBLE NOISE | 53dBA at 1 meter (noise less room) typical |
| OPERATING TEMPERATURE | 10°C to +40°C, +45°C with 7.5% derating; Batteries recommended max. +25°C |
| STORAGE TEMPERATURE | -15°C to +25°C |
| RELATIVE HUMIDITY | 0-95%, non condensing |
CERTIFICATIONS |
|
| SAFETY CERTIFICATIONS | UL1778 5th Edition, CSA C22.2 No. 107.3-14, NOM-NYCE |
| EMC COMPLIANCE | 47 CFR Part 15/ICES-003 Class A |
| QUALITY | ISO 9001:2015, ISO 14001:2004 |
| SURGE | ANSI C62.41 Category B3, IEC 61000-4-5Â |
| MARKINGS | cULus, NOM-NYCE |
You must be logged in to post a review.