FGCEVDP10MMRM/0I-UPS EVO DSP PLUS RACK MOUNT 10.0 – PF 0.9 – MADE IN ITALY
- For Local Area Network (LAN), Data Centers
- Power factor 0,9
- Rectifier realized by IGBT technology
- Compatible with Generators
- Battery charging system controlled by microprocessor
- Static Bypass
- UPS Management Software TecnoManager compatible
- with Windows, Mac OS X, Unix, Linux, etc.
Product Technical Specifications:
Code / Part Number |
FGCEVDP10MMRM/0I |
| Nominal power | 10 KVA |
| Active power | 9 KW |
| Power factor | 0,9 |
| Technology | On-Line Double Conversion transformerless (VFI-SS-111) |
| Cooling | Fan cooling |
| Audible noise | < 48 dBA to 1 m |
| Dimension (UPS) WxHxD | 43,8×13.3×58 cm (3U) |
| Dimension (with packing) WxHxD | 59x26x78,5 cm |
| Weight | 18 Kg |
| Equipped with | 1 serial cable, Tecnomanager software and 2 metal handle for 19’’ Rack cabinet mounting |
Input FGCEVDP10MMRM/0I |
|
| Number of phases | 1Ph+N |
| Nominal voltage | 208Vac/220Vac/230Vac/240Vac |
| Input voltage range | 176Vac-300Vac from 50% to 100% load, 110Vac-300Vac from to 50% load |
| Nominal frequency | 50/60 Hz (selectable) |
| Input frequency range On-Line mode | ±7% |
| Input power factor | 0,99 |
Output FGCEVDP10MMRM/0I |
|
| Number of phases | 1Ph+N |
| Nominal voltage | 208Vac/220Vac/230Vac/240Vac |
| Voltage Regulation at 0 linear load (On-Line and Battery mode) | ±1% |
| Voltage THD | <3% (linear load), <6% (non-linear load) |
| Crest factor | 3:1 |
| Frequency | 50/60 Hz (selectable) |
| Frequency stability | ±0,1 Hz |
| Inverter waveform | Sinewave |
| Overload capability (Line mode) | 110% for 10 minutes, 130% for 1 minute, >130% for 1 second |
| Overload capability (Battery mode) | 110% for 30 seconds, 130% for 10 seconds, >130% for 1 second |
| Efficiency | 94%, calculated in double conversion mode at 100% load to 100% load according to standard 62040-3 |
| Transfer time | 0 ms (On-Line) |
| Output connections | Terminal block |
Battery (fitted inside the external Battery Box) |
|
| Batteries number | 16 (inside the external Battery Box, for UPS operation) |
| Battery charge time (typical) | 6-8 hours |
| Extended autonomy | External Battery Box (optional) |
Environmental specification FGCEVDP10MMRM/0I |
|
| Working temperature | Da 0 a 55 °C (recommended from 20 to 25 °C) |
| Humidity | < 95% without condensation |
| Maximum altitude | 3000 m |
| IP protection | IP20 |
| Certifications | CE (standards: Low Voltage Directive IEC EN 62040-1; EMC Directive IEC EN 62040-2; classification IEC EN 62040-3) |