ABB PowerValue 11T G2 Single-phase UPS from 1 kVA to 10 kVA

BrandABB
15 People watching this product now!
Category:
Description

PowerValue 11T G2 Single-phase UPS from 1 kVA to 10 kVA

ABBƒ??s PowerValue 11T G2 is a single-phase in/out, double conversion online uninterruptible power supply (UPS) that guarantees up to 10 kW per single UPS of clean, reliable power for your critical single-phase applications. As well as maintaining power to your server room, advertising display, turnstiles, lab equipment, transportation signaling systems, ATM or vending machine, the PowerValue 11T G2 also conditions incoming power to eliminate spikes, swells, sags, noise and harmonics.

Featuring voltage and frequency independent (VFI) topology, the tower-only PowerValue 11T G2 saves costs by minimizing energy losses with its double conversion efficiency of up to 95 percent (up to 98% in ECO mode). Two or three units can be connected in parallel to boost power delivery to a maximum of 30 kW or to provide redundancy.

Simple to install or maintain, inexpensive to run and with the most compact online UPS footprint available on the market, the PowerValue 11T G2 provides stable, regulated, transient-free, pure sine wave AC power with extremely tight output voltage regulation. All units can be fitted with up to four external battery modules (EBMs) to extend runtime to well over two hours. Each EBM is dedicated to its corresponding UPS and setup is easily accomplished via the LCD menu.


GENERA DATA

UPS frame rated power

1 / 2 / 3 / 6 / 10 kVA

UPS module rated power

–

UPS output rated PF

0.9 – 1.0

Max no of parallel frames

Up to 3 units (model dependent)

Max no of parallel modules across frames

–

Max system power

30 kW

Wiring 1-ph + N + PE
UPS type Standalone tower

Topology

Online double conversion

INPUT

Nominal input voltage

220 / 230 / 240 VAC (1 – 3 kVA)
208 / 220 / 230 / 240 VAC (6 – 10 kVA)

Voltage range

100 – 300 VAC (1 – 3kVA)
100 – 276 VAC (6 – 10 kVA)

Frequency range

45 – 55 Hz / 54 – 66 Hz
45 – 55 Hz / 54 – 66 Hz (extendable to 40~70 Hz at load 60%)

Current THD at 100% load

5% with full resistive load (1 – 3 kVA)
3% with full resistive load (6 – 10 kVA)

Power Factor at 100% load

ƒ?0.99 (1 – 3 kVA)
ƒ?0.995 (6 – 10 kVA)

OUTPUT

Rated output voltage (load dependent)

220 / 230 / 240 VAC (1 – 3 kVA)
208 / 220 / 230 / 240 VAC (6 – 10 kVA)

Voltage THD (with linear load)

2% linear load, 6% non linear load (1 – 3 kVA)
1% linear load, 5% non linear load (6 – 10 kVA)

Rated frequency

50 or 60 Hz

EFFICIENCY

Double conversion

Up to 95%

Eco-mode

Up to 98%

COMMUNICATIONS

User interface

LCD

Communication ports

SNMP; ModBus; AS400; Environmental monitoring sensor probe

Software

Monitoring and shutdown software available as option