Code FGCEVDP6MMRM/00
Nominal power 6 KVA
Active power 5,4 KW
Power factor 0,9
Technology On-Line Double Conversion transformerless (VFI-SS-111)
Cooling Fan cooling
Audible noise 48 dBA to 1 m
Dimension (UPS) WxHxD 43,8×8,8×50 cm (2U)
Dimension (with packing) WxHxD 59x22x71 cm
Weight 15 Kg
Equipped with 1 serial cable, Tecnomanager software and 2 metal handle for 19’’ Rack cabinet mounting
Input
Number of phases 1Ph+N
Nominal voltage 208Vac/220Vac/230Vac/240Vac
Input voltage range 176Vac-300Vac from 50% to 100% load, 110Vac-300Vac from to 50% load
Nominal frequency 50/60 Hz (selectable)
Input frequency range On-Line mode ±7%
Input power factor 0,99
Output
Number of phases 1Ph+N
Nominal voltage 208Vac/220Vac/230Vac/240Vac
Voltage Regulation at 0 linear load (On-Line and Battery mode) ±1%
Voltage THD 3% (linear load), 6% (non-linear load)
Crest factor 3:1
Frequency 50/60 Hz (selectable)
Frequency stability ±0,1 Hz
Inverter waveform Sinewave
Overload capability (Line mode) 110% for 10 minutes, 130% for 1 minute, >130% for 1 second
Overload capability (Battery mode) 110% for 30 seconds, 130% for 10 seconds, >130% for 1 second
Efficiency 94%, calculated in double conversion mode at 100% load to 100% load according to standard 62040-3
Transfer time 0 ms (On-Line)
Output connections Terminal block
Battery (fitted inside the external Battery Box)
Batteries number 16 (inside the external Battery Box, for UPS operation)
Battery charge time (typical) 6-8 hours
Extended autonomy External Battery Box (optional)
Environmental specification
Working temperature Da 0 a 55 °C (recommended from 20 to 25 °C)
Humidity 95% without condensation
Maximum altitude 3000 m
IP protection IP20
Certifications CE (standards: Low Voltage Directive IEC EN 62040-1; EMC Directive IEC EN 62040-2; classification IEC EN 62040-3)
 Code FGCEVDP6MMRM/00
Nominal power 6 KVA
Active power 5,4 KW
Power factor 0,9
Technology On-Line Double Conversion transformerless (VFI-SS-111)
Cooling Fan cooling
Audible noise 48 dBA to 1 m
Dimension (UPS) WxHxD 43,8×8,8×50 cm (2U)
Dimension (with packing) WxHxD 59x22x71 cm
Weight 15 Kg
Equipped with 1 serial cable, Tecnomanager software and 2 metal handle for 19’’ Rack cabinet mounting
Input
Number of phases 1Ph+N
Nominal voltage 208Vac/220Vac/230Vac/240Vac
Input voltage range 176Vac-300Vac from 50% to 100% load, 110Vac-300Vac from to 50% load
Nominal frequency 50/60 Hz (selectable)
Input frequency range On-Line mode ±7%
Input power factor 0,99
Output
Number of phases 1Ph+N
Nominal voltage 208Vac/220Vac/230Vac/240Vac
Voltage Regulation at 0 linear load (On-Line and Battery mode) ±1%
Voltage THD 3% (linear load), 6% (non-linear load)
Crest factor 3:1
Frequency 50/60 Hz (selectable)
Frequency stability ±0,1 Hz
Inverter waveform Sinewave
Overload capability (Line mode) 110% for 10 minutes, 130% for 1 minute, >130% for 1 second
Overload capability (Battery mode) 110% for 30 seconds, 130% for 10 seconds, >130% for 1 second
Efficiency 94%, calculated in double conversion mode at 100% load to 100% load according to standard 62040-3
Transfer time 0 ms (On-Line)
Output connections Terminal block
Battery (fitted inside the external Battery Box)
Batteries number 16 (inside the external Battery Box, for UPS operation)
Battery charge time (typical) 6-8 hours
Extended autonomy External Battery Box (optional)
Environmental specification
Working temperature Da 0 a 55 °C (recommended from 20 to 25 °C)
Humidity 95% without condensation
Maximum altitude 3000 m
IP protection IP20