Tecnoware FGCEVDP6503MMI-UPS EVO DSP PLUS 6.5 – PF 0,9 12 BATTERIES 12VDC 9AH Made in Italy
- Complete protection from blackout, voltage fluctuations (overvoltages and undervoltages), lightning (with upstream arrester), frequency variations, surge, harmonics, voltage distortions
- Recommended for Local Area Networks (LAN), Data Centers, Industry, Electromedical Equipments
- Intelligent slot for SNMP, Dry Contact or MODBUS card
- On-Line Double Conversion technology transformerless (VFI-SS-111)
- Active PFC circuit (0.99)
- Compatibility with generator
- Static bypass
Technical specifications FGCEVDP6503MMI
| Code | FGCEVDP6503MMI |
| Nominal power | 6.5 KVA |
| Active power | 5.8 KW |
| Power factor | 0,9 |
| Technology | On-Line Double Conversion transformerless (VFI-SS-111) |
| Cooling | Fan cooling |
| Audible noise | < 48 dBA to 1 m |
| Dimension (UPS) WxHxD | 19×57,3×36,9 cm |
| Dimension (with packing) WxHxD | 33×83,5×50,5 cm |
| Weight | 46 Kg |
Input |
|
| Number of phases | 1Ph+N |
| Nominal voltage | 208Vac/220Vac/230Vac/240Vac |
| Input voltage range | 176Vac-300Vac from 50% to the 100% of loading, 110Vac-300Vac up to 50% load |
| Nominal frequency | 50/60 Hz (selectable) |
| Input frequency range (On-Line mode) | ±7% |
| Input power factor | 0,99 |
Output |
|
| Number of phases | 1Ph+N |
| Nominal voltage | 208Vac/220Vac/230Vac/240Vac |
| Voltage Regulation at 0 linear load (On-Line and Battery mode) | ±2% |
| Voltage THD at rated linear load | <3% (linear load), <5% (non-linear load) |
| Crest factor | 3:1 |
| Frequency | 50/60 Hz (selectable) |
| Frequency stability | ±0,1 Hz |
| Inverter waveform | Sinewave |
| Overload capability (Line mode) | 110% for 30 minutes, 130% for 5 minutes, >130% for 10 seconds |
| Overload capability (Battery mode) | 110% for 3 minutes, 130% for 30 seconds, >130% for 10 seconds |
| Efficiency | 94%, calculated in double conversion mode at 100% load to 100% load according to standard 62040-3 |
| Transfer time | 0 ms (On-Line) |
Battery |
|
| Type | Lead acid, sealed, maintenance free |
| Installed inside | 12 elements |
| Extended autonomy | – |
Environmental specification |
|
| Working temperature | From 0 to 55 °C (recommended from 20 to 25 °C) |
| Humidity | < 95% without condensation |
| Maximum altitude | 3000 m |
| IP protection | IP20 |
| Certifications | CE (Standards: Low Voltage Directive IEC EN 62040-1; EMC Directive IEC EN 62040-2; classification IEC EN 62040-3) |
Additional information
| Ups Capacity |